Repair

Update Software

When software is updated on the ADM, the software is
then automatically updated on all connected GCA com-
ponents. A status screen is shown while software is
updating to indicate progress.
1. Turn the system main power switch OFF.
2. Remove the ADM from the bracket.
3. Remove the token access panel.
4. Insert and press the software upgrade token (T)
firmly into the slot.
NOTE: There is no preferred orientation of the token.
T
5. Install the ADM into the bracket.
6. Turn the system main power switch ON.
A status is shown while software is updating to indi-
cate progress. To prevent corrupting the software
load, do not remove the token until the status
screen disappears.
58
NOTICE
NOTE: When the Screen turns on, you will see the fol-
lowing screens:
First:
Software is checking which
GCA modules will take the
available updates.
Second:
Status of the update with
approximate time until
completion.
Third:
Updates are complete.
Icon indicates update suc-
cess/failure. See the fol-
lowing Icon table.
Icon
Description
Update successful.
Update unsuccessful.
Update complete, no changes necessary.
Update was successful/complete, but one
or more HCA modules did not have a CAN
boot-loader, so software was not updated
on that module.
7. Remove the token (T).
8. Replace the token access panel.
9. Press
to continue to the operation screens.