Mechanical Setup - Graco Therm-O-Flow 200 Instructions - Parts Manual

Bulk hot melt system
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Setup

Mechanical Setup

1. Fill displacement pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL™) for Butyl and PSA mate-
rials.
NOTE: Use IsoGuard Select
for PUR or reactive Polyurethane material. IGS is
designed to dissolve and suspend the Polyurethane
materials. IGS will solidify after a period of time and
should be replaced once the solidified lube does not
return to liquid form after heating.
F
. 7: Wetcup
IG
2. Turn all air regulators to their full counterclockwise
position. See Integrated Air Controls, page 9.
3. Connect a 1/2 in. (13 mm) air line from an air source
to the system air inlet (H), capable of delivering a
minimum of 25-50 cfm at 100 psi (0.7 MPa, 7.0 bar).
Do not use quick disconnects.
F
. 8: Air Connection
IG
16
®
(IGS) (part no. 24F516)
H
4. Ensure drum low and empty sensors (C) are
mounted as shown.
NOTE: The Drum Low and Empty Sensors are used to
indicate that a drum is empty. The kit contains a sensor
mounting bracket (A), activator (B), sensors (C1, C2),
and a cable for connecting the panel inside the electrical
enclosure.
A
C1
C2
5. Increase the distance between the low (C1) and
empty (C2) sensors to increase the heat up time for
the tandem secondary system. Lower the drum
empty sensor (C2) to force the heated platen lower
into the drum. If empty sensor is set too low, the
pump could cavitate and cause an alarm.
B
334130L