4.3.5.2 Setting SW6 Input Switches
SW6 switches 1, 3, 4, 5, 6 define input type
In a recorder model having a display and keypad the input switches at SW6 must be set to match the type of
input to be used. The location of SW6 is shown in Figure 4-3. The appropriate switch settings for the
various input types are shown in Table 4-3.
Note that the setting of switch 2 in SW6 is not related to input type. It is used, along with the "BRNOUT"
parameter in the input group, to specify the effects of an input failure as described in Subsection 4.3.5.3.
ATTENTION
The ON position for SW6 switches is toward the left side of the printed circuit assembly (when
facing recorder.)
Table 4-3 SW6 Input Switch Settings for Models
Input Type
0 V to 1 V
0 V to 2 V
0 V to 5 V
0 V to 10 V
2 V to 10 V
1 V to 5 V
0 mV to 10 mV
0 mV to 100 mV
0 to 200 mV
0 mA to 20 mA
4 mA to 20 mA
all thermocouples
all RTDs

This switch is used to select whether the input value used by the recorder
should be driven over range or under range in case of input failure. See
Subsection 4.3.5.3.
80
Having Display and Keypad
SW6 Input Switch Settings
1
2

off

off

off

off

off

off

off

off

ON

off

off

off
off
off
DR4300 Circular Chart Recorder Product Manual
3
4
5
6
off
off
off
ON
off
off
off
ON
off
ON
off
off
off
off
off
ON
off
off
off
ON
off
off
off
ON
off
off
ON
off
off
off
ON
off
off
off
off
off
off
off
ON
ON
off
off
ON
ON
off
off
ON
off
off
off
ON
ON
SW6 Input Switch
6
5
4
3
2
1
4/00