Table 4-25 Procedure For Starting The Recorder - Honeywell DR4300 Product Manual

Circular chart recorder
Hide thumbs Also See for DR4300:
Table of Contents

Advertisement

DR4300 Circular Chart Recorder
4.4.4.5 Startup procedure
Procedure
Use the procedure listed in Table 4-25 to start the recorder.
Open the recorder door (if the recorder does not have the optional keypad on the outside of the door).
Apply power and wait for the recorder to run its power-up tests.
ATTENTION
If FAILSF or another error message starts blinking in the lower display, refer to Section 8 for
troubleshooting information.
For recorders with control on both pens, be sure the INP '1' indication is lit for steps 2 to 6. If INP 1
is not lit, press the FUNC key until "1" is lit when "INP" is displayed.
Step
Pen check
1
2
Select manual
mode
3
Adjust the output
Confirm correct
4
configuration.
126

Table 4-25 Procedure for Starting the Recorder

Operation
Press
MAN
AUTO
RESET
DISP
or
SET
UP
DR4300 Circular Chart Recorder Product Manual
Action/Result
For models without outputs, check that the pen is
operating and skip to Step 4.
Until "M" indicator is ON. Be sure INP 1 indicator is lit.
If it is not, press FUNC key. The recorder is in
manual mode and the Output (OT) in percent is
displayed in the lower display.
Calls up OT value in the lower display.
Adjust the output value and ensure that the final
control element is functioning correctly.
Upper Display
shows the input value.
Lower Display
shows OT and the output
value in %.
If you want to check the recorder's configuration,
follow the procedure described earlier in this section. If
you try to change a value and can not, a lockout is
enabled; see Subsection 4.3.19.