Procedure
Table 7-3 explains how to troubleshoot a pen trace problem.
Step
Check the ink cartridge for proper
1
installation.
Check that the chart agrees with the
2
actuation type and chart set up.
Check the pen alignment.
3
Look at printed circuit assembly (PCA) for
4
the pen to see if the red* LED is lit. This
LED is lit when the PCA failed a self-
diagnostic, or an out-of-range input has
been detected. (Flashing green LED is
OK, it indicates that the processor is
active.)
5
Check the sensor for the proper type and
its ability to function.
Replace the servo plate assembly.
6
7
Replace the printed circuit assembly for
the pen with the problem.
166

Table 7-3 Troubleshooting Pen Trace Failure Symptoms

What to do
DR4300 Circular Chart Recorder Product Manual
How to do it or
where to find the instructions
Reposition or replace the ink cartridge as
described in Section 6 – Routine Maintenance.
If the pen arm is severely warped, replace the
pen arm as described in Section 9 – Replacing
Hardware Assemblies.
Replace wrong chart with correct chart. Refer to
Section 3 – Configuration, Startup, and
Operation of Recorder without Display for
instructions for viewing the configuration.
See Section 6 – Routine Maintenance for
instructions for replacing the chart.
Follow the procedure in Subsection 7.4.
Press the reset switch SW2. The PCA will be
initialized. If the problem was a software error,
the error may be cleared by the reset.
*For Recorders with a display, the red LED is
used by an internal control signal and is not a
fault indicator.
Verify the input configuration data and operation
of the sensor.
Measure input signal at TB2 or apply calibration
source to verify input signal.
Refer to the replacement procedure in Section 9
– Replacing Hardware Assemblies.
Refer to the replacement procedure in Section 9
– Replacing Hardware Assemblies.