6.2 Replacing the Chart

Procedure
Refer to Figure 6-1 and follow the procedure in Table 6-1 to replace the chart.
Step
1
Turn off the power to the recorder, then open the door.
Pull up on the pen lifter to raise the pen(s) from the chart plate.
2
3
Lift the chart from the hub, and slide it from under the pen(s) to remove it from the chart plate.
Slip the new chart under the pen lifter, pens and time index; and press the chart into place
4
over the chart hub.
5
Turn the chart until the desired time line on the chart is aligned with the time index on the
chart plate and pen 1 before closing the locking clip on the hub. Push down on the lifter to
return the pen(s) to the chart.
CAUTION: Do not try to rotate the hub
Close the door and apply power.
6
Pen arm
Time index
Pen lifter
158

Table 6-1 Procedure for Replacing the Chart

Ink
Clip
cartridge

Figure 6-1 Replacing the Chart and Ink Cartridge

DR4300 Circular Chart Recorder Product Manual
Action
Notch for
Open
pen tip
clip
24214
Pen
tip
Large chart
hub