7.3.2 Recorder Failure Troubleshooting
Procedure
Table 7-2 explains how to troubleshoot recorder failure symptoms.
Step
Check the supply voltage.
1
Check the connections to TB1 on the
2
pen 1 PCA.
Check the system for brown-outs,
3
heavy load switching, etc.; and
conformance to installation
instructions.
Replace the PCA for pen 1.
4
4/00
Table 7-2 Troubleshooting Recorder Failure Symptoms
What to do
DR4300 Circular Chart Recorder Product Manual
Troubleshooting and Pen Alignment
of Recorder without Display
How to do it or
where to find the instructions
Measure the line voltage across the line and neutral
connections at TB1 on the printed circuit assembly
(PCA) on the right (for pen 1).
Refer to ac wiring procedures in Section 2 –
Installation.
Refer to Section 2 – Installation.
Refer to the replacement procedures in Section 9 –
Replacing Hardware Assemblies.
165