buttons within 60 seconds, the menu changes to display the charging progress.
You can switch the front panel display to the menu at any time by pressing
the select button again.
5. Press and release the up or down button until the Node: option is displayed
on the first line of the front-panel display.
6. Verify that the node number that is displayed on the second line of the
front-panel display is the same as the node number that is printed on the
front panel of the node. Figure 71 shows how the node number appears on
the front panel.
N o d e :
x x x x x x
Figure 71. Node number
7. Press and release the up or down button until the Ethernet option is shown
on the front panel display. The second line of the front-panel display in
Figure 72 shows the message Inactive. This message indicates that, although
an Ethernet connection is available, it cannot yet be used.
E t h e r n e t :
I n a c t i v e
Figure 72. Ethernet mode
8. Press and release the up or down button until the FC Port-1 option shows in
the display.
9. Check whether the second line of the front-panel display shows the message
Active. If Active is not shown on the second line, go to "MAP 5600: Fibre
channel" in the IBM System Storage SAN Volume Controller: Service Guide to
repair the fault.
10. If you are installing a SAN Volume Controller 2145-8F2, go to step 16. If you
are installing a SAN Volume Controller 2145-8F4, go to step 11.
11. Press and hold the down button.
12. Press and release the select button.
13. Release the down button. The operational speed of the fibre-channel link is
displayed. Use the cable connection table that is provided by the customer to
verify that the fibre-channel link is operating at the expected speed. If the
operational speed does not match the expected speed, go to "MAP 5600: Fibre
channel" in the IBM System Storage SAN Volume Controller: Service Guide to
repair the fault.
14. Press the select button to return to the fibre-channel status display.
15. Press the right button to display each port in turn and repeat the above speed
check. Go to step 18 on page 98
16. Press and release the left or right button to display the other port options.
Check whether for each port, the second line of the front-panel display shows
the message Active. If Active is not shown for any port, go to "MAP 5600:
Fibre channel" in the IBM System Storage SAN Volume Controller: Service Guide
to repair the fault.
Appendix A. SAN Volume Controller 2145-8F4 and SAN Volume Controller 2145-8F2
97