Advertisement

IBM UPS 7500XHV
IBM UPS 10000XHV
Uninterruptible Power Supply
Operation and Setup Guide
25R5636

Advertisement

Table of Contents
loading

Summary of Contents for IBM UPS 7500XHV

  • Page 1 IBM UPS 7500XHV IBM UPS 10000XHV Uninterruptible Power Supply Operation and Setup Guide 25R5636...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety ......................................1 1: INSTALLATION..................................4 Introduction ....................................4 Unpacking....................................4 Removing the Battery Modules..............................4 Positioning the Uninterruptible Power Supply ......................... 5 Hardwiring the Uninterruptible Power Supply......................... 5 Mounting the Uninterruptible Power Supply in a Rack and Attaching the Front Bezel............6 Installing and Connecting the Batteries and Attaching the Front Battery Bezel..............
  • Page 5: Safety

    Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
  • Page 6 Antes de instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. WARNING: Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm.
  • Page 7 CAUTION! Handling Safety Use safe practices when lifting. <18 kg (<40 lb) 32–55 kg (70–120 lb) 18–32 kg (40–70 lb) >55 kg (>120 lb) >10º CAUTION! Electrical Safety Electrical Current from power, telephone, and communication cables is hazardous. Please read the following safety statements. •...
  • Page 8: 1: Installation

    ® The IBM UPS 7500XHV and UPS 10000XHV models are high-performance uninterruptible power supplies, designed to pre- vent blackouts, brownouts, sags, and surges from reaching your computer and other sensitive electronic equipment. The uninter- ruptible power supply filters small utility line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line.
  • Page 9: Positioning The Uninterruptible Power Supply

    Number Voltage Current External Wire Size Full Load Circuit Breaker (typical) Phases (Nominal) (typical) UPS 7500XHV Input 200/208/220/230/240 V 38 amps 50 amps / 2-pole 10 mm Input 380/400/415 V 14 amps / phase 50 amps / 4-pole 10 mm...
  • Page 10: Mounting The Uninterruptible Power Supply In A Rack And Attaching The Front Bezel

    Switch the uninterruptible power supply input circuit breaker (see A in the diagram that follows) and the utility circuit breakers off. Remove the access panel (see B in the diagram). Remove the circular knockouts on the access panel. Run wires through the access panel to the terminal blocks. Connect the wire to the ground block first. Adhere to all national and local electrical codes.
  • Page 11: Installing And Connecting The Batteries And Attaching The Front Battery Bezel

    Secure the uninterruptible power supply in the rack. Attach the front bezel. Installing and Connecting the Batteries and Attaching the Front Battery Bezel Install all battery modules. Connect the batteries. Reinstall and secure the battery doors with the captive Attach the front battery bezel. screws.
  • Page 12: Tower Configuration

    Tower Configuration Attention: Before converting to a tower configuration, remove the battery modules (see Removing the Battery Modules). Remove the rail guides. Bring the unit to tower position, and remove the display bezel by sliding to the left and out. Rotate the display bezel and reinstall.
  • Page 13: Connecting Equipment And Power To The Rear Panel Of The Uninterruptible Power Supply

    Power management software and serial port communication can be used with the uninterruptible power supply. Use only cables supplied or ap- proved by IBM. Note: Use the supplied serial cable to connect to the serial port. Do not use a standard serial interface cable because it is incompatible with the uninterruptible power supply connector.
  • Page 14: Selecting The Output Voltage Via Terminal Mode

    Selecting the Output Voltage via Terminal Mode Terminal Mode is a menu driven interface that enables enhanced configuration of the uninterruptible power supply. Connect the serial cable to the serial port on the back of the uninterruptible power supply. ® When using the PowerChute Network Shutdown utility: Exit the PowerChute Business Edition agent and server using the following steps:...
  • Page 15: 2: Operation

    2: O PERATION Front Display Panel NDICATOR ESCRIPTION Online This LED is lit when the uninterruptible power supply is supplying utility power to the connected equipment and performing double conversion to supply power to the con- nected equipment. If not lit, the uninterruptible power supply is either not turned on, or is supplying battery power.
  • Page 16: On Battery Operation

    EATURE UNCTION Diagnostic Utility The uninterruptible power supply has a diagnostic feature that displays the utility volt- Voltage age. Note: The uninterruptible power supply starts a self-test as part of this procedure. The self-test does not affect the voltage display. Press and hold the button to view the utility voltage bar graph display.
  • Page 17 UPS 7500XHV Model: Number of Battery Packs Load (W) Internal 7.56 13.83 21.50 37.68 6.00 10.93 17.06 29.83 4.16 7.65 11.93 20.90 3.16 5.83 9.11 16.00 2.51 4.68 7.36 12.89 2.11 3.91 6.12 10.75 1.80 3.33 5.25 9.23 1.56 2.90 4.52...
  • Page 18: 3: User Configurable Items

    3: U ONFIGURABLE TEMS ETTINGS ARE MADE THROUGH THE SUPPLIED OWER HUTE USINESS DITION SOFTWARE ETWORK ANAGEMENT OR TERMINAL MODE EFER TO THE SOFTWARE HELP GUIDES FOR DETAILS ACTORY ELECTABLE UNCTION ESCRIPTION EFAULT HOICES Automatic Self-Test Every 14 days Every 7 days This function sets the interval at which (336 hours) (168 hours),...
  • Page 19: Emergency Power Off (Epo) Option

    ETTINGS ARE MADE THROUGH THE SUPPLIED OWER HUTE USINESS DITION SOFTWARE ETWORK ANAGEMENT OR TERMINAL MODE EFER TO THE SOFTWARE HELP GUIDES FOR DETAILS ACTORY ELECTABLE UNCTION ESCRIPTION EFAULT HOICES Output Frequency Automatic Automatic, The user is able to set the allowable 50 ±...
  • Page 20: 4: Storage, Maintenance, Shipping, And Service

    Customer Service, a technician will ask you to describe the problem and attempt to solve it over the phone, if possible. If the uninterruptible power supply or one of its components is faulty, IBM will send you a replacement CRU for the un- interruptible power supply or the component.
  • Page 21: 5: Hardware Maintenance Information

    This chapter contains information about IBM customer replaceable unit (CRU) availability for the UPS 7500XHV and UPS 10000XHV models. Customer Replaceable Unit Part Numbers IBM CRU part numbers are subject to change without notice. This section contains a listing of the CRU part numbers available at the time this document was published. CRU P...
  • Page 22: 6: Troubleshooting

    6: T ROUBLESHOOTING Use the chart below to solve minor uninterruptible power supply installation and operation problems. Refer to IBM for assis- tance with complex uninterruptible power supply problems. ROBLEM AND OSSIBLE OLUTION AUSE UNINTERRUPTIBLE POWER SUPPLY WILL NOT TURN ON...
  • Page 23 ROBLEM AND OSSIBLE OLUTION AUSE BYPASS AND OVERLOAD LEDS ARE LIT UNINTERRUPTIBLE POWER SUPPLY EMITS A SUSTAINED ALARM TONE The uninterruptible power sup- The connected equipment exceeds the specified maximum load. ply is overloaded. The con- The alarm remains on until the overload is removed. Disconnect nonessen- nected equipment is drawing tial equipment from the uninterruptible power supply to eliminate the over- more VA or more watts than...
  • Page 24: 7: Getting Help And Technical Assistance

    ECHNICAL ASSISTANCE If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This chapter contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your xSeries or IntelliStation system, and whom to call for service, if it is necessary.
  • Page 25: Replacement Part Handling

    Pack the uninterruptible power supply or the faulty component in packaging sent by IBM, and use the return label to ship back to IBM. Pack the uninterruptible power supply properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under war- ranty.
  • Page 26: 8: Notices, Trademarks, And Radio Frequency Warnings

    APC and IBM do not permit the use of any of their products in direct patient care. APC and IBM will not knowingly sell their products for use in such applications.
  • Page 27: Edition Notice

    In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment.
  • Page 28: Electronic Emission Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.IBM is not responsible for any radio or television interference causedby using other than recommended cables and connectors or by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 29 Taiwan electronic emission statement Chinese Class A warning statement Statement of Conformity to the Voluntary Control Council for Interference from Informa- tion...

This manual is also suitable for:

Ups 10000xhv

Table of Contents