Brocade G610 Technical Specifications
This document highlights the features and specifications for the Brocade G610 switch.
System specifications
System component
Enclosure
Power inlet
Power supplies
Fans
Cooling
System architecture
System processors
Port-to-port latency
Fibre Channel
System component
Fibre Channel ports
ANSI Fibre Channel protocol
Modes of operation
Fabric initialization
FCIP (IP over Fibre Channel)
Port Status
Other
System component
Serial console port
Brocade G610 Hardware Installation Guide
53-1004408-08
Description
1U, nonport-side intake airflow, port-side power inlet
C13; power from port side
Single, fixed power supply
Four built-in fans
Nonport-side to the port side
Nonblocking shared memory switch
Freescale T1022E CPU
<900 nanoseconds with no contention (destination port is free) including FEC using cut-through frame switching.
Description
24 SFP+ ports (8-port increments through capacity-based Ports on Demand (PoD) licenses) that support any
combination of Short Wavelength (SWL) and Long Wavelength (LWL) or Extended Long Wavelength (ELWL)
optical media.
The SFP+ ports are capable of auto-negotiating to 4, 8, 16, or 32 Gbps speed depending on the SFP+ model
and the minimum supported speed of the optical transceiver at the other end of the link.
•
4-, 8-, and 16-Gbps performance is enabled by 16-Gbps SFP+ transceivers provided the other end
of the connection has a minimum of 4 Gbps speed set on the port.
•
8-, 16-, and 32-Gbps performance is enabled by 32-Gbps SFP+ transceivers provided the other end
of the connection has a minimum of 8 Gbps speed set on the port.
NOTE
2-, 4-, and 8-Gbps transceivers are not supported.
Fibre Channel Physical and Signaling Interface standard (FC-PH)
Fibre Channel Class 2 and Class 3
Complies with FC-SW-3 Rev. 6.6
Complies with FC-IP 2.3 of FCA profile
Bicolor LED (amber/green)
Description
One three-wire (Tx, Rx, Gnd) UART serial port