Device Overview; Hardware Features - Brocade Communications Systems G610 Hardware Installation Manual

Table of Contents

Advertisement

Device Overview

Hardware features..............................................................................................................................................................................................11

License options.................................................................................................................................................................................................. 12
Port-side view..................................................................................................................................................................................................... 12
Nonport-side view.............................................................................................................................................................................................13
Device management options........................................................................................................................................................................13
Hardware features
The Brocade G610 switch offers the following features and capabilities:
Up to 24 auto-sensing ports supporting 32-Gbps SFP+ technology in a single domain.
Dynamic Ports on Demand (Dynamic-POD) scaling from a base configuration of 8 ports to 24 ports (two 8-port SFP+ POD).
4-, 8-, 16-, and 32-Gbps auto-sensing Fibre Channel switch ports.
A 32-Gbps optical transceiver can auto-negotiate to 32 Gbps, 16 Gbps, or 8 Gbps.
A 16-Gbps optical transceiver can auto-negotiate to 16 Gbps, 8 Gbps, or 4 Gbps.
NOTE
The port speed is determined by the maximum speed supported by the optical transceivers at the either end of the
link.
Universal ports self-configure as a E_Ports, F_Ports, M_Ports, or D_Ports.
A Diagnostic Port (D_Port) provides diagnostics, troubleshooting, and verification services for the physical media.
One built-in fixed power supply unit (not a FRU) with a port-side power inlet.
Four integrated fans (no fan FRUs) for cooling the system. This allows a single fan failure and permits the switch to continue to
function properly if a fan fails. Only nonport-side intake airflow for cooling is supported.
If one fan fails and the temperature is less than 56C, the fans run at high speed. If the temperatures increases more than
56C, a critical temperature warning is displayed and the device shuts down in two minutes.
If two fans fail and the temperature is less than 55C, the fans run at high speed. If the temperature increases more than
55C, a critical temperature warning is displayed and the device shuts down in two minutes.
If the third fans fails, a warning is displayed and the device is immediately shut down.
Hardware-enabled input and output (I/O) latency statistics collection.
Hardware-enabled VM support.
1U chassis that can be installed as a standalone unit or mounted in a standard Electronic Industries Association (EIA) 48.26cm
(19 inches) cabinet or rack.
Support for Brocade small form-factor pluggable plus (SFP+) optical transceivers in any combination of Short Wavelength
(SWL), Long Wavelength (LWL), or Extended Long Wavelength (ELWL) optical media.
Extended distance Fibre Channel to support long distance native FC connectivity.
Port-to-port latency is minimized to 900 nanoseconds including FEC using cut-through frame switching at 32 Gbps.
A dual-core T1022E processor operating at 1.2 GHz delivers high performance, scalability, and advanced Fabric Vision