Promag TR510E Manual page 30

Express time recorder
Table of Contents

Advertisement

activated. Each bell table entry consists of two fields: 'time' field (set through
these 32 group-1 registers) and a corresponding 'enable/disable' field (set
through group-1 registers 22H-41H).
Bell table (Everyday mode), enable/disable (group-1 registers 22H-41H)
Set
Command
CRR,SS
Reply
A
Get
Command
BRR
Reply
ASScc
RR- register number (group 1) in the Hex form (22H-41H), SS- state (00:
disabled, 01: enabled), cc- checksum
The TR510E features a relay that can be used for external bell control. In
Everyday mode only one bell table can be set for everyday use. Up to 32
different bell times can be specified for which the bell will be activated. Each
bell table entry consists of 2 fields: 'time' field (set through group-1 registers
02H-21H) and a corresponding 'enable/disable' field (set through these group-1
registers).
Example: programming a bell table entry for 12:00:00
First, set the desired time; select a time register that you haven't used yet
(i.e. 05H). Set the time using the following command: "C05,1200". Next, enable
this time through a corresponding enable/disable register. The corresponding
enable/disable register for time register 05H is 25H (time registers start from
02H, enable/disable registers start from 22H, we use the 4
group). Enable command looks like this: "C25,01".
Event selection mode (group-1 register 42H)
Set
Command
C42,EE
TR510E User's Manual
30
Possible error codes:04, 07
Possible error codes: 04, 07
th
register of each
Possible error codes: 04, 07