R-command will be denied temporarily until all data sending finish.
Note: When first time turn power-up for TR510E after received 'R'
command, it will take 25 seconds to restore all factory defaults, in the
meanwhile LED will display "INIT"; please wait for this initialization procedure to
complete:
Set group-1 register ('C', 43H)
Command
CRR,reg_data
Reply
A
RR- register number (group 1) in Hex form (00H...FFH); reg_data- the data
for the register to be set
This command is used to set one of the TR510E "group-1 registers".
Registers are actually functioning parameters (Settings). Complete description
of all available registers can be found in Section 4.
Get group-1 register ('B', 42H)
Command
BRR
Reply
Areg_datacc
RR- register number (group 1) in Hex form (00H...FFH), reg_data is the
data stored in the register, cc- checksum
This command is used to retrieve the data contained in the designated
"group-1 register". Registers are actually functioning parameters (settings).
Complete description of all available registers can be found in Section 4.
Set group-2 registers ('P', 50H)
TR510E User's Manual
15
Possible error codes: 04, 07
Possible error codes: 04, 07
Possible error codes: 04, 07