Promag TR510E Manual page 22

Express time recorder
Table of Contents

Advertisement

recovered even with the M-command.
When real-time data transmission function is enabled (please see L-
command for detailed description) and sending data to host is in progress, then
Z-command will be denied temporarily until all data sending finish.
Note: When turn power-up at first time for TR510E after self-test, it will take
25 seconds to restore all factory defaults, please wait for this initialization
procedure; the LED will display "INIT" while initialization is in progress:
Extended command-set description:
Log into Extended mode ('i', 69H)
Command
i (the lower case of 'I')
Reply
A
This command logs the TR510E into Extended mode whatever TR510E is
currently in Extended mode or not, but if TR510E is enabled in real-time data
transmission mode, the i-command will be denied. If you want to use other
extended commands TR510E should be logged into Extended mode first. In
Extended mode, TR510E can send the captured data to Host in Real-time.
Log out from Extended mode ('o', 6FH)
Command
o (the lower case of 'O')
Reply
A
This command logs the TR510E out from Extended mode. When TR510E
has logged out from Extended mode, TR510E cannot use extended commands
anymore except commands 'i', 'o', and 's'.
TR510E User's Manual
22
Possible error codes: 09
Possible error codes: none

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Promag TR510E