Command
T
Reply
AYYYYMMDDhhmmss
YYYY-year, MM- month, DD-date, hh-hour, mm-minutes, ss- seconds
This command is used to get the TR510E's current date and time.
Get firmware version ('V', 56H)
Command
V
Reply
Aversion_string
Version_string length is guaranteed to not exceed 61 character, all
character codes are guaranteed to be in the 20H...7FH range
This command can be used to verify the TR510E's internal firmware version.
Although version string can be any ASCII string, the following format is adopted:
"VX.X cc.......c", where "VX.X" is a version number (i.e. "V1.92") and
"cc...c" is a comment string. Comment string is separated from the version
number by a single space character. Version number will never have any
spaces in it.
Initialize the terminal ('R', 52H)
Command
R
Reply
A
This command is used to initialize the TR510E. Initialization takes place on
the next power-up, not immediately. Upon initialization, all setting values are
restored to their factory defaults. TR510E's internal date and time are also
checked and, if contained garbage, initialized to 1999/01/01 and 00:00:00
respectively. The database data is not be erased, this must be done using the
E-command.
When real-time data transmission function is enabled (please see L-
command for detailed description) and sending data to host is in progress, then
TR510E User's Manual
14
Possible error codes: none
Possible error codes: 09