Promag TR510E Manual page 16

Express time recorder
Table of Contents

Advertisement

Command
PRR,reg_data
Reply
A
RR- register number (group 2) in Hex form (00...FFH), reg_data is the data
for the register to be set
This command is used to set one of the TR510E "group-2 registers".
Registers are actually functioning parameters (Settings) with respect to access
bell table 'time' field (7x32 entries) from Sunday to Saturday. Complete
description of all available registers can be found in Section 4.
Get group-2 registers ('Q', 51H)
Command
QRR
Reply
Areg_datacc
RR- register number (group 2) in Hex form (00H...FFH), reg_data is the
data stored in the register, cc- checksum
This command is used to retrieve the data contained in the designated
"group-2 registers". Registers are actually functioning parameters (settings) with
respect to access bell table 'time' field (7x32 entries) from Sunday to Saturday.
Complete description of all available registers can be found in Section 4.
Set group-3 registers ('J', 4AH)
Command
JRR,reg_data
Reply
A
RR- register number (group 3) in Hex form (00...FFH), reg_data is the data
for the register to be set
This command is used to set one of the TR510E "group-3 registers".
Registers are actually functioning parameters (Settings) with respect to access
bell table 'enable/disable' field (7x32 entries) from Sunday to Saturday.
Complete description of all available registers can be found in Section 4.
TR510E User's Manual
16
Possible error codes: 04, 07
Possible error codes: 04, 07