Express time recorder
Table of Contents

Advertisement

Extended command-set (for Real-time access control function):
Summarized below are all supported extended commands using in
extended mode. Command characters are found in the "CC" column (all
extended commands are lower case), their corresponding ASCII codes- in "Hex".
"CS" lists commands that require the checksum in the command packet ("C") or
reply packet ("R"). "Error code" column lists errors that may result from each
command execution:
C.
Hex
C.
'i'
69H
'o'
6FH
's'
73H
'n'
6EH
'r'
72H
'a'
61H
'd'
64H
'l'
6CH
'p'
70H
'u'
75H
Following is the detailed command description. Command and reply
packets are shown without STX, Checksum and CR characters.
Select designated terminal ('D', 44H)
Command
DNN
Reply
ANN,TR510E
TR510E User's Manual
Description
Log into Extended mode
Log out from Extended mode
Get current login status
Terminal sends captured-data to
Host
Host requires Terminal to resend
the captured data
Host acknowledges that data has
received successfully
Host sends "4 digits" message to
display
Host sends the "Relay activation"
duration. (The command 'l' is lower
case of 'L')
Set punch times
Get punch times
Possible error codes: none