4. Registers

The TR510E feature 3 groups of programmable "registers". Basically,
registers are the TR510E's functioning parameters (Settings). Group-1 registers
can be written to using the C-command, and read from using the B-command;
Group-2 registers can be written to using the P-command, and read from using
the Q-command; Group-3 registers can be written to using the J-command, and
read from using the K-command (see Section 3 for details).
Table below lists all available group-1 registers:
00H
01H
02H-21H
22H-41H
42H
43H
44H-63H
64H-83H
84H
85H-86H
87H
88H
89H
8AH
8BH
8CH
8DH-92H
Table below lists all available group-2 registers:
00H-1FH
20H-3FH
LED display mode (0: wall-mount, 1:desktop)
Bell duration in seconds (00H-FFH)
Bell table, times (total of 32 registers)
Bell table, enable/disable (total of 32 registers)
Event selection mode, free (IN or OUT), IN only, OUT only,
or Scheduled
Relay function (0: for Alarm, 1: for Door unlock)
Event table, times (total of 32 registers)
Event table, event selection (IN: 1, OUT: 0)
Bell table mode, Everyday or Week (Everyday: 0, Week: 1)
Daylight Saving Time (start-date ~ end-date)
Enable or Disable Daylight Saving Time function
Door unlock duration in seconds (00H-FFH)
Prefix to match (0-16 characters)
From character (extract from a character position in the ID-
code, this setting is from 1 to 37)
Number of characters (extract a portion of code from ID-
card, this setting is from 1 to 37)
Allow or disallow record duplication (1:allow, 0:disallow)
Unexpected ID-code (0-37 characters)
Bell table of Sunday, 'time' field (32 registers)
Bell table of Monday, 'time' field (32 registers)