turn out to be invalid, its contents are substituted for a "safe" default data:
ID-code. If ID-code turns out to contain illegal characters (i.e. with
codes outside of 20H-7FH range), then these characters are
substituted for "_". If ID-code length is outside of valid margins then
entire ID-code is substituted for the following code: "0000000000" (ten
'0' characters)
Date. If the date is invalid (i.e. December, 32
(1999/01/01) is used
Time. If the time is invalid (i.e. 24:00:00) then default time is used
Event. If Event code exceeds 1, then this field is substituted for "0".
Note: for JIS-II code, the valid length of ID-code is "1<= margin <=69"; for
Track1 code, the valid length of ID-code is "1<= margin <=76"; for Track2 code,
the valid length of ID-code is "1<= margin <=37".
Host require sending captured data again ('r', 72H)
Command
r (the lower case of 'R')
Reply
nNNNN,ccc...c,E,YYYY/MM/DD,hh:mm:sscc
NNNN- record number in Hex form, ccc...c- ID-code, E- event (0: OUT, 1:
IN), YYYY- year, MM-month, DD-date, hh-hour, mm- minute, ss- second, cc-
checksum
If data receiving is failure host can require TR510E to resend currently
captured record by this command. And then TR510E will resend the currently
captured record by 'n' (6EH) command again, see 'n' (6EH) command
description for details.
If TR510E is not in extended mode, this command will be denied.
Host acknowledges data received successfully ('a', 61H)
Command
a (the lower case of 'A')
Reply
TR510E User's Manual
24
nd
) then default date
Possible error codes: 07, 09
Possible error codes: none