Praesideo| Service manual | Chapter
LED indications
7.1
LED indication Network splitter
Yellow
(1)
Green
(Error)
(Power)
Off
Off
On
Off
Off
On
7.2
LED indication Fibre Interface
Yellow
(1)
Green
(Fault)
(Power)
OFF
OFF
On
OFF
On
On
OFF
On
OFF
Blinking
On
Blinking
Bosch Security Systems | 2004-28 | 3922 880 62312
(2)
Status
No power.
Wrongly connected or network error.
Functioning correctly.
(2)
Status
OFF; no external power available
Standby; external power to POF is switched off
Operating; external power to POF switched on
(incase external power has been connected and afterwords been
removed stays this yellow LED on. It will be off when the power
from the pof side is removed)
Operating; no external power available, but powered from the
POF side
Fault; No external power available and no communication with the
Network Controller (Check the POF cables/connections and
external power supply)
Fault, external power available, but no communication with the
Network Controller (Check the POF cables/connections)
en | 15