No. Problem
The batteries are not
16
being charged
The batteries are not
17
being charged
The batteries are not
18
being charged
Operating time with
19
charged batteries too
short
1) Additional symbols in the display fi eld are possible
Indicators
Possible causes
1)
K123
???
Stop
No power from charger
LED
Red
1)
K123 ???
No power from charger
LED
Off
1)
K123 ???
Defective rechargeable batteries
LED
Off
Battery display changes
Charging procedure aborted. The
to uncharged within a
batteries are used/too old.
short time.
If application of the above instructions does not result in elimination of the fault,
please contact Demag customer service.
Notes, section in this document
Check connection to charger
and mains connector. Replace
defective plug-in charger, if
necessary.
Check connection to charger
and mains connector. Replace
defective plug-in charger, if
necessary.
Replace rechargeable batteries,
8.2 and 8.3.
Repeat charging procedure, 8.1
and 8.2