Connecting an AC power cable
CAUTION:
NEPS3500-A requires a 16 A power cable (AC), so you must use a 16 A busbar and make sure the
AC power source can provide enough power.
The following procedure uses the AC power supply that comprises one 3500 W AC power frame and
two 1800 W power supplies to show how to install AC power cables.
To connecting an AC power cable:
Insert the ends of the bail latch into the holes on the left side of the upper power supply.
1.
Connect one end of the AC power cable to the AC receptacle on the module.
2.
Use a wiring tie through a notch of the bail latch, and bend the power cable so that the wiring
3.
tie can bind the power cable with the bail latch.
Repeat steps 2 and 3 to bind another power cable with a wiring tie through the other notch.
4.
Connect the other end of the AC power cable to the external power supply system.
5.
Figure 16 Connecting a NEPS3500-A AC power cable
Connecting DC power cables
The DC power cables for the NEPS2000-D and NEPS3500-D are connected in the same way. The
procedure in this section uses the NEPS2000-D.
17