Field
XFP
RX loss of signal
RX not ready
RX CDR loss of lock
TX fault
TX not ready
TX CDR loss of lock
Module not ready
APD supply fault
TEC fault
Wavelength unlocked
RX power high
RX power low
TX power high
TX power low
TX bias high
TX bias low
Temp high
Temp low
Voltage high
Voltage low
Transceiver info I/O error
Transceiver info checksum error
Transceiver type and port configuration
mismatch
Transceiver type not supported by port
hardware
# Display the currently measured values of the fault detection parameters for the transceiver module
plugged in interface GigabitEthernet 3/1/1.
<Sysname> display transceiver diagnosis interface Gigabitethernet 3/1/1
GigabitEthernet3/1/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C)
Voltage(V)
36
3.31
Remarks
RX signal is lost.
RX is not ready.
RX clock cannot be recovered.
TX fault.
TX is not ready.
TX clock cannot be recovered.
Module is not ready.
Avalanche Photo Diode (APD) supply fault.
Thermoelectric Cooler (TEC) fault.
Wavelength of optical signal exceeds the manufacturer's
tolerance.
RX power is high.
RX power is low.
TX power is high.
TX power is low.
TX bias current is high.
TX bias current is low.
Temperature is high.
Temperature is low.
Voltage is high.
Voltage is low.
Transceiver information read and write error.
Transceiver information checksum error.
Transceiver type does not match port configuration.
Transceiver type is not supported on the port.
Bias(mA)
RX power(dBM)
6.13
-35.64
41
TX power(dBM)
-5.19