Make sure the maximum total output power of the power supplies exceeds the system power
consumption. (HP recommends reserving a certain power de-rating value.) For the maximum
output power of a single power supply, see
HP recommends that you configure N+1 or N+M power supply redundancy.
To use the AC power supply, select the 16 A AC power cables. For the 16A AC power cables
used in different countries or regions, see
The NEPS3500-A AC power frame functions properly only if you install one or two NEPS1800-A
AC power supplies.
Table 36 Power supply electrical specifications
Model
Description
3500 W AC
NEPS3500-A
power frame
1800 W AC
NEPS1800-A
power supply
2000 W DC
NEPS2000-D
power supply
3500 W DC
NEPS3500-D
power supply
Table 37 16 A AC power cables for countries or regions
No.
Specifications
Connector
type
1
I type
Connector outline
Table
Table
Rated input voltage
range
100 VAC to 240
VAC; 50 Hz or 60 Hz
100 VAC to 240
VAC; 50 Hz or 60 Hz
–60 VDC to –48 VDC
–60 VDC to –48 VDC
Countries or regions
where the type of
power cables
Code
conforms to local
(Length)
safety regulations
and can be used
legally
040433
96 (3 m
Mainland China
or 9.8 ft)
Power cable outline
80
36.
37.
Max
Max input
input
voltage range
current
90 VAC to 264
VAC; 50 Hz or
2×16A
60 Hz
16 A @
110
90 VAC to 264
VDC
VAC; 50 Hz or
12 A
60 Hz
@220
VDC
45 A @
–75 VDC to –36
–-48
VDC
VDC
80 A @
–75 VDC to –36
–-48
VDC
VDC
Other countries
or regions using
this type of
power cables
Max output
power
3500 W (when
installed with two
AC power
supplies)
1200 W (100
VAC to 120 VAC)
1800 W (200
VAC to 240 VAC)
2000 W
3500 W
Countries or regions
seldom using this type
of power cables
Connector outline