5.2 Details of Function Codes

This section provides the details of the function codes frequently used for the FRENIC-Mini series of
inverters.
For details about the function codes given below and other function codes not given below,
refer to the FRENIC-Mini User's Manual (24A7-E-0023), Chapter 9 "FUNCTION CODES."
F00

Data Protection

F00 specifies whether to protect function code data (except F00) and digital reference data
(such as frequency command, PID command and timer operation) from accidentally getting
changed by pressing the
Data for F00
0
1
2
3
Enabling the protection disables the
To change F00 data, simultaneous keying of
keys is required.
Even when F00 = 1 or 3, function code data can be changed via the
communications link.
For similar purposes, WE-KP, a signal enabling editing of function code data from
the keypad is provided as a terminal command for digital input terminals. (Refer to
the descriptions of E01 through E03.)
F01, C30

Frequency Command 1, Frequency Command 2

F01 or C30 sets the command source that specifies reference frequency 1 or reference
frequency 2, respectively.
Data for
F01, C30
0
1
/
keys.
Disable both data protection and digital reference protection,
allowing you to change both function code data and digital reference data with
the
/
keys.
Enable data protection and disable digital reference protection,
allowing you to change digital reference data with the
cannot change function code data (except F00).
Disable data protection and enable digital reference protection,
allowing you to change function code data with the
cannot change digital reference data.
Enable both data protection and digital reference protection,
not allowing you to change function code data or digital reference data with the
/
keys.
Enable
/
keys on the keypad.
(Refer to Chapter 3 "OPERATION USING THE KEYPAD.")
Enable the voltage input to terminal [12] (0 to +10 VDC, maximum frequency
obtained at +10 VDC).
Function
/
keys to change function code data.
+
(from 0 to 1) or
Function
5-21
/
keys. But you
/
keys. But you
+
(from 1 to 0)