• Deliver this manual to the end user of this product. Keep this manual in a safe place until this product is discarded. • For instructions on how to use an optional device, refer to the instruction and installation manuals for that optional device. Fuji Electric Co., Ltd. INR-SI47-2242a-E...
Preface Thank you for purchasing our FRENIC-Lift LM2C series of inverters. FRENIC-Lift LM2C is an inverter designed to drive a three-phase induction motor (hereafter called induction motor) and a three-phase permanent magnet synchronous motor (hereafter called synchronous motor) for exclusively controlling elevating machinery. Improper handling might result in incorrect operation, a short life, or even a failure of this product as well as the motor.
Page 4
Installation • Install the inverter on a base made of metal or other non-flammable material. Otherwise, a fire could occur. • Do not place flammable object nearby. Doing so could cause fire. • Do not support the inverter by its front cover during transportation. Doing so could cause a drop of the inverter and injuries.
Page 5
• Ensure that the number of input phases and the rated voltage of the product match the number of phases and the voltage of the AC power supply to which the product is to be connected. Otherwise, a fire or an accident could occur. •...
Page 6
• If the user configures the function codes wrong without completely understanding this Instruction Manual and the FRENIC-Lift LM2C series Reference Manual, the motor may rotate with a torque or at a speed not permitted for the machine. An accident or injuries could occur. •...
Page 7
Maintenance and inspection, and parts replacement • Before proceeding to maintenance or inspection, turn OFF the power and wait at least 10 minutes. Make sure that the charging lamp is turned OFF. Further, make sure, using a multimeter or a similar instrument, that the DC link bus voltage between the terminals P(+) and N(-) has dropped to the safe level (+25 VDC or below).
Conformity to the Low Voltage Directive in the EU If installed according to the guidelines given below, inverters marked with CE are considered as compliant with the Low Voltage Directive. Compliance with European Standards Adjustable speed electrical power drive systems (PDS). Part 5-1: Safety requirements.
Page 9
Conformity to the Low Voltage Directive in the EU (Continued) 5. The inverter should be used in an environment that does not exceed Pollution Degree 2 requirements. If inverters are to be used in an environment with pollution Degree 3 or 4, place them in an enclosure of IP54 or above.
Page 10
Conformity to the Low Voltage Directive in the EU (Continued) 10. The inverter has been tested according to IEC/EN 61800-5-1 Short-circuit Test under the following conditions. Short-circuit current in the supply: 10,000 A 480V or below (400V class series inverters) 11.
Conformity with Canadian standards and U.S. standards The inverters with CSA “C/US” marking are subject to the regulations set forth by the Canadian and U.S. standards by installation within precautions listed below. 1. Solid state motor overload protection (motor protection by electronic thermal overload relay) is provided in each model.
Page 12
Conformity with Canadian standards and U.S. standards (Continued) 4. Use wires listed in CSA or UL. Copper wire size AWG (mm Main terminal *1 Main power input Inverter Inverter type outputs Inverter’s [U, V, W] grounding [ G] FRN0010LM2C-4 (2.1) FRN0015LM2C-4...
Page 13
Conformity with Canadian standards and U.S. standards (Continued) 5. Install CSA or UL certified fuses or Circuit breaker between the power supply and the inverter, referring to the table below. Circuit breaker (MCCB) Fuse rating [A] RCD/ELCB etc (Class) Inverter type With Without With...
1) In the event that breakdown occurs during the product's warranty period which is the responsibility of Fuji Electric, Fuji Electric will replace or repair the part of the product that has broken down free of charge at the place where the product was purchased or where it was delivered. However, if the following cases are applicable, the terms of this warranty may not apply.
Page 15
Depending on the request, these can be discussed separately. [ 6 ] Applicable scope of service Above contents shall be assumed to apply to transactions and use in the country where you purchased the products. Consult your local supplier or Fuji Electric representative for details. xiii...
Table of Contents Preface................... i Safety precautions ..............i Conformity to the Low Voltage Directive in the EU ....vi Conformity with Canadian standards and U.S. standards ..ix Product warranty ..............xii Chapter 1 BEFORE USE ..........1-1 1.1 Acceptance Inspection and Appearance of Product ..............
Chapter 1 BEFORE USE 1.1 Acceptance Inspection and Appearance of Product Unpack the package and check the following: (1) An inverter and the following accessories are contained in the package. Instruction manual (this book) Main circuit wiring connector (2) The inverter has not been damaged during transportation—there should be no dents or parts missing. (3) The inverter is the type you ordered.
Page 19
If you suspect the product is not working properly or if you have any questions about your product, contact your Fuji Electric representative. PG interface card is available to the following ROM versions. ...
(1) The maximum wiring distance between an inverter and a motor The maximum wiring is 20m. When using wire longer than the specification, that may not be able to control a motor. If longer secondary wiring is required, consult your Fuji Electric representative. Power input...
1.3.2 Storage environment The storage environment in which the inverter should be stored after purchase differs from the usage environment. Store the inverter in an environment that satisfies the requirements listed below. [1] Temporary storage Table1.1 Storage and Transport Environments Item Specifications Storage temperature *1...
Chapter 2 MOUNTING AND WIRING THE INVERTER 2.1 Installing the Inverter (1) Mounting base Install the inverter on a base made of metal or other non-flammable material. Do not mount the inverter upside down or horizontally. (2) Clearances Ensure that the minimum clearances indicated in Figure 2.1 and Table 2.1 are maintained at all times.
2.2 Wiring Follow the procedure below. In the following description, it is assumed that the inverter has already been installed. 2.2.1 Removing the front cover ① Remove the keypad blind cover and loosen the screws ② Hold the right and left ends of the front cover and remove it. Blind cover Screw Front cover...
2.2.3 Wire sizes For the wire sizes for the main circuits, refer to the "Conformity to the Low Voltage Directive in the EU" given in Preface. Terminals for the main circuits should have insulation, insulation tubes, or similar treatment. 2.2.4 Terminal arrangement diagrams and screw specifications The tables and figures given below show the screw specifications and terminal arrangement diagrams.
Page 25
◆ FRN0010LM2C-4□ to FRN0025LM2C-4□ Short circuit terminals Grounding terminals (For manufacturer) 24VDC input terminals Input terminals Output terminals Main circuit terminals Output Main circuit Short circuit 24VDC input Grounding Input terminals terminals terminals Terminals terminals terminals (For manufacturer) ◆ FRN0032LM2C-4□ Short circuit terminals Grounding terminals (For manufacturer)
Page 26
Connection method with shield plate of input and output terminals. Tightwire (FRN0010LM2C-4□ to FRN0032LM2C-4□) (FRN0039LM2C-4□ / FRN0045LM2C-4□)
Page 27
(2) Arrangement of control circuit terminals Table 2.3 Control Circuit Terminals Screw specifications Wire strip length Recommended Type of screwdriver Terminal block type wire size (mm (tip shape) Screw Tightening size torque 0.20 to 3.31 mm Flat screwdriver Relay terminals M2.5 0.39±10% N·m (AWG24 to 12)
DC link bus terminals P(+), N(-) When you need to use the DC link bus terminals P(+) and N(-), consult your Fuji Electric representative. The three-phase input power lines or single-phase input L1/R, L2/S, power lines are connected to these terminals.
Page 29
Wiring notes To make the machinery or equipment compliant with the EMC standards, wire the motor and inverter in accordance with the following. (*3) Use shielded wires for the motor cable and route the cable as short as possible. Firmly clamp the shield to the grounded metal plate.
Page 30
Control circuit terminals Table 2.5 Names, Symbols and Functions of the Control Circuit Terminals Classifi- Name Symbol Functions cation Analog setting voltage input [12] External voltage input that commands the frequency externally. (1) Input voltage range : 0 to ±10VDC / 0 to ±100% (2) Hardware specifications ・Input impedance : 22 kΩ...
Page 31
Table 2.5 Names, Symbols and Functions of the Control Circuit Terminals (continued) Classifi- Name Symbol Functions cation Enable input 1 [EN1] (1) Opening the circuit between terminals [EN1] and [PLC] or Enable input 2 [EN2] terminals [EN2] and [PLC] stops the operation of the inverter output transistorby STO functional safety function according to IEC/EN 61800-5-2.
Page 32
Table 2.5 Names, Symbols and Functions of the Control Circuit Terminals (continued) Classifi- Name Functions Symbol cation These terminals output monitor signals for analog DC voltage (-10 Analog monitor [FMA] Analog to +10 V). output Analog common Common terminal for analog output signals. [11] Both the SINK and SOURCE modes are supported.
Page 33
Table 2.5 Names, Symbols and Functions of the Control Circuit Terminals (continued) Classifi- Name Symbol Functions cation General-purpose relay [Y3A/C] (1) Any one of output signals that can be assigned to terminals [Y1] outputs [Y4A/C] and [Y2] can also be assigned to this relay contacts, as a [Y5A/C] general-purpose relay output, in order to use it for outputting a signal.
2.2.6 Connection diagrams This section shows connection diagrams with the Enable input function used. FRN0010LM2C-4□ to FRN0032LM2C-4□ DC REACTOR EXTERNAL BRAKING DCR (*3) RESISTOR (PLC) or (CM) (*7) (THR) RCD: Residual-current-operated protective device ELCB: Earth Leakage Circuit Breaker MCCB: Molded Case Circuit Breaker P(+) N(-) Fuse...
Page 35
(*1) Install a recommended molded case circuit breaker (MCCB) or residual-current-operated protective device (RCD)/earth leakage circuit breaker (ELCB) (with over current protection function) in the primary circuit of the inverter to protect wiring. (*2) Refer to table 2.4. In 230 V mode, use it only during rescue operation, and do not connect during normal operation.
Page 36
FRN0039LM2C-4□ to FRN0045LM2C-4□ DC REACTOR EXTERNAL BRAKING DCR (*3) RESISTOR (PLC) or (CM) (*7) (THR) P(+) N(-) Fuse MCCB or (*6) RCD/ELCB (*1) L1/R Motor Three-phase Power supply (*4) L2/S -Filter Refer to (*13) L3/T 1.Standard specfications (SCCF) Auxiliary control power input (*2) Refer to External Contactor...
Page 37
(*1) Install a recommended molded case circuit breaker (MCCB) or residual-current-operated protective device (RCD)/earth leakage circuit breaker (ELCB) (with over current protection function) in the primary circuit of the inverter to protect wiring. (*2) Even if this terminal is not connected, the inverter can be operated with connection of the main circuit (L1/R, L2/S, L3/T).
2.2.7 Setting the slide switches on the control PCB Switching the slide switches located on the control PCB (see Figure 2.4) allows you to customize the operation mode of the analog output terminals, digital I/O terminals, and communications ports. To access the slide switches, remove the front cover so that you can see the control PCB. ...
Chapter 3 OPERATION USING THE KEYPAD The FRENIC-Lift has no standard keypad. Using the optional multi-function keypad allows you to start and stop the motor, monitor running status, and switch to the menu mode. You may also set the function code data, monitor I/O signal states, maintenance information, and alarm information.
Chapter 4 RUNNING THE MOTOR FOR A TEST 4.1 Checking Prior to Powering ON Check the following before powering on the inverter. (1) Check that the wiring is correct. Especially check the wiring to the inverter input terminals L1/R, L2/S and L3/T and output terminals U, V, and W.
4.3 Configuring the Function Code Data Before Test Run Configure the function codes listed below according to the motor ratings and your machinery design values. For the motor ratings, check the ratings printed on the motor's nameplate. For your machinery design values, ask system designers about them.
4.4 Running the Inverter for Motor Operation Check After preparations of 4.1-4.3 have been completed, begin to perform the test drive of the motor. Turn on both terminals [EN1] and [EN2] before running the motor. If terminals [EN1] or [EN2] and [PLC] are not connected, the motor doesn’t rotate. ------------------------------- Test Run Procedure using the multi-function keypad (option) ------------------------------ (1) Turn the power ON and check that the LCD monitor blink while indicating a reference speed of 0.00.
Chapter 5 TROUBLESHOOTING 5.1 Alarm Codes Table 5.1 Quick List of Alarm Codes Code Name Description The inverter momentary output current exceeded the overcurrent level. Instantaneous overcurrent OC1: Overcurrent during acceleration OC2: Overcurrent during deceleration OC3: Overcurrent during running at a constant speed Zero-phase current caused by ground fault in the output Ground fault circuit has exceeded the allowable limit.
Page 44
Table 5.1 Quick List of Alarm Codes(Continued) Code Name Description The inverter detects a broken wiring connection in the Broken wiring in the PG pulse encoder. A communications error has occurred during CANopen CANopen communication error communication. Over speed prevention The motor speed is higher than maximum speed * L32.
Chapter 6 MAINTENANCE AND INSPECTION Perform daily and periodic inspections to avoid trouble and keep reliable operation of the inverter for a long time. 6.1 Daily Inspection Visually inspect the inverter for operation errors from the outside without removing the covers when the inverter is ON or operating.
These parts are likely to deteriorate with age due to their construction and properties, leading to the decreased performance or failure of the inverter. When the replacement is necessary, consult your Fuji Electric representative. Table 6.2 Replacement Parts Standard replacement intervals (See Notes below.)
6.4 Inquiries about Product and Guarantee 6.4.1 When making an inquiry Upon breakage of the product, uncertainties, failure or inquiries, inform your Fuji Electric representative of the following information. Inverter type (Refer to Chapter 1, Section 1.1.) SER No. (serial number of the product) (Refer to Chapter 1, Section 1.1.)
Chapter 7 SPECIFICATIONS 7.1 Standard Model 1) Three-phase 400V series Item Specifications 0032 0039 0045 Type FRN___LM2C-4□ 0010 0015 0019 0025 Nominal applied motor [kW] 18.5 Rated capacity [kVA] Three-phase 380V-480V, 50/60Hz Rated voltage 21.4 10.0 15.0 18.5 (24.5) 32.0 39.0 45.0 Rated current...
Page 49
*7) Braking time and duty cycle (%ED) are defined by cycle operation at the rated regenerative power as shown in the figure below. Regenerative power [kW] Reated regenerative power Time [s] Braking time : T Braking time : T %ED = ×100 Cyclic period :T *8) Measured at 1m from inverter.
Page 50
Specifications for use with three-phase 230V mode Item Specifications 0032 0039 0045 Type FRN___LM2C-4□ 0010 0015 0019 0025 Nominal applied motor [kW] 12.7 Rated capacity [kVA] Three-phase 220V-230V, 50/60Hz Rated voltage 21.4 15.0 18.5 (24.5) 32.0 Rated current Overload capacity [A] 27.0 33.3 44.1...
Page 51
*7) Braking time and duty cycle (%ED) are defined by cycle operation at the rated regenerative power as shown in the figure below. Regenerative power [kW] Reated regenerative power Time [s] Braking time : T Braking time : T %ED = ×100 Cyclic period :T *8) Measured at 1m from inverter.
7.2 External Dimensions Power supply voltage Inverter type FRN0010LM2C-4□ FRN0015LM2C-4□ Three-phase 400V FRN0019LM2C-4□ FRN0025LM2C-4□...
Page 53
Power supply voltage Inverter type Three-phase 400V FRN0032LM2C-4□ Power supply voltage Inverter type FRN0039LM2C-4□ Three-phase 400V FRN0045LM2C-4□...
<Precaution when exporting to Europe> ●Not all Fuji Electric products in Europe are necessarily imported by the above importer. If any Fuji Electric products are exported to Europe via another importer, please ensure that the importer is clearly stated by the customer.
Compliance with European Standards The CE marking on Fuji products indicates that they comply with the essential requirements of the Electromagnetic Compatibility (EMC) Directive, Low Voltage Directive, Machinery Directive and Lift Directive which are issued by the Council of the European Communities. The products comply with the following standards Table 8.1 Product Standards Compliance FRN0010LM2C-4□...
EMC Directive. Therefore, CE marking for the equipment shall be the responsibility of the equipment manufacturer. For this reason, Fuji Electric’s CE mark is indicated under the condition that the product shall be used within equipment meeting all requirements for the relevant Directives. Instrumentation of such equipment shall be the responsibility of the equipment manufacturer.
4) If radiated noise emissions exceed the requirement by the standard, place a ferrite core on the input side of the inverter, as shown in Figure 8.2. Ferrite Core FRENIC-Lift L1/R From L2/S Power L3/T Supply Figure 8.2 Installation for ferrite core Harmonic Component Regulation in the EU 8.5.1 General comments When general-purpose industrial inverters are used in the EU, the harmonics emitted from inverters to the...
8.6 Compliance with Functional Safety Standard 8.6.1 General In FRENIC-Lift series of inverters, opening the hardware circuit between terminals [EN1]-[PLC] or between terminals [EN2]-[PLC] stops the output transistor, coasting the motor to a stop (EN: Enable input). This is the Safe Torque Off (STO) compliant with Functional Safety Standard EN/IEC 61800-5-2.
Page 59
Enable terminals and peripheral circuit, and internal circuit configuration Conventional Inverter Safety circuit breakers complying with more than EN ISO 13849-1 Cat.3 Power supply External safety switch complying with more than EN ISO 13849-1 Cat.3, PL-e “Enable” input EN62061/EN61508 SIL3 Reset Emergency Stop Figure 8.4 Conventional Inverters compliant with...
Table 8.4 Operation of STO Functional Safety Function Digital input signals Alarm ECF Digital output signal Inverter status [EN1] [EN2] [Y*] (DECF) Shorted Shorted No issue Ready to run Issue Output shutdown (STO) Opened Opened No issue Output shutdown (STO) Issue Output shutdown (STO) Shorted...
Page 61
under Pollution Degree 3 environment the safety circuit that implements the STO functional safety function will not reduce its performance. Therefore, the STO function operation can be ensured even under Pollution Degree 3. - To bring the inverter into compliance with Functional Safety Standard, it is necessary to bring it into compliance with European Standards EN61800-5-1 and EN61800-3.
8.6.3 Inverter output state when Safe Torque Off (STO) is activated Turning the emergency stop button ON turns EN1 and EN2 OFF, bringing the inverter into the Safe Torque Off (STO) state. Figure 8.6 shows the timing scheme to apply when the emergency stop button is turned OFF with the inverter being stopped.
Page 63
Figure 8.7 shows the timing scheme to apply when the emergency stop button is turned ON with the inverter running. Input signals to EN1 and EN2 go OFF, bringing the inverter into the Safe Torque Off (STO) state and coasting the motor to a stop. Stop Run command Emergency stop...
8.6.4 ECF alarm (caused by logic discrepancy) and inverter output state Figure 8.8 shows the timing scheme to apply when EN1 and EN2 inputs are not concordant, so that an alarm ECF occurs. Turning the emergency stop button ON turns EN1 and EN2 inputs OFF, which usually brings the inverter into the Safe Torque Off (STO) state.
8.7 Compliance with Canadian and U.S. Standards (CSA certification) 8.7.1 General The inverters with CSA “C/US” marking are certified for both U.S. and Canadian markets, to the applicable U.S. and Canadian standards. The products comply with the following standards Table 8.5 Product Standards Compliance FRN0010LM2C-4□...
Page 66
In no event will Fuji Electric Co., Ltd. be liable for any direct or indirect damages resulting from the application of the information in this manual.
Page 67
Fuji Electric Co., Ltd. Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan Phone: +81 3 5435 7058 Fax: +81 3 5435 7420 http://www.fujielectric.com/...