No.
8
9
10
11
12
13
SINAMICS V-ASSISTANT Online Help
Operating Manual, 02/2015, A5E32187373-003
Name
Descriptions
MBR
Motor holding brake
1: motor holding brake is closed
0: motor holding brake is released
Note: MBR is only status signal because the
control and the power supply of the motor hold-
ing brake is realized with separate terminals.
OLL
Overload level reached
1: motor has reached the parameterizable
output overload level (P_overload_level in %
of rated torque, default: 100%, max: 300%)
0: motor has not reached the overload level
WARNIN
Warning 1 condition reached
G1
1: parameterizable warning 1 condition has
been reached.
0: warning 1 condition has not been
reached.
See note below.
WARNIN
Warning 2 condition reached
G2
1: parameterizable warning 2 condition has
been reached
0: warning 2 condition has not been
reached.
See note below
REFOK
Referenced
1 = Referenced
0 = Not referenced
CM_STA
Current control mode
1 = The second mode in five compound
control modes (PTI/S, IPos/S, PTI/T, IPos/T,
S/T)
0 = The first mode in five compound control
modes or four basic modes (PTI, IPos, S, T)
Task navigation
4.3 Commissioning
Control mode
PTI
IPos
S
X
X
T
X