Siemens SINAMICS V90 Operating Manual page 47

Sinamics v-assistant online help
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

● In internal position control mode, you must specify position setpoint on the following panel:
Linear axis or modular axis can be used depending on your actual application.
– The linear axis has a restricted traversing range and it is the factory setting of the
– The modular axis has an unrestricted traversing range.
You can directly enter the digital value in the cells for the following items:
– Position
– Speed
– Acceleration
– Deceleration
The current active position setpoint channel is displayed at the bottom of this panel. The
channels correspond with p2617 and p2618 as follows:
SINAMICS V-ASSISTANT Online Help
Operating Manual, 02/2015, A5E32187373-003
SINAMICS V90 servo drive.
Position setpoint channel
0
1
2
3
4
5
6
7
Index of p2617
0
1
2
3
4
5
6
7
Task navigation
4.2 Parameterizing
Index of p2618
0
1
2
3
4
5
6
7
47