Siemens SINAMICS V90 Operating Manual page 65

Sinamics v-assistant online help
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Area Item
SINAMICS V-ASSISTANT Online Help
Operating Manual, 02/2015, A5E32187373-003
Pulse train input
DI1~DI8
DI9
DI10
Note:
For more information about the number and definition of signals, refer to Section"Digital inputs
(DIs) (Page 67)".
AI1
AI2
Note:
For more information about analog inputs, refer to Section "Analog inputs (AIs) (Page 74)".
AO1
AO2
Note:
For more information, refer to Section "Analog outputs (AOs) (Page 75)".
DO1~DO6
Signal is enabled
Signal is disabled
Signal is forcedly set
to 1
Description
Information about pulse train input:
Received number of pulses.
Pulse frequency.
For more information, refer to Section "Pulse train inputs
(PTIs) (Page 76)".
Every digital input can be linked with either of the 28
internal signals.
Linked with EMGS signal.
Linked with C_MODE signal.
Linked with speed related signals.
Linked with torque related signals.
Linked with actual speed signal by default.
Linked with actual torque signal by default.
Every digital output can be freely linked with either of the
12 internal signals. For more information, refer to Section
"Digital outputs (DOs) (Page 72)".
Clicking this button enables DO simulation. If you desire
to disable this function, click the following button:
Indicates high-voltage (or logic 1) is on the digital in-
put/output.
Indicates low-voltage (or logic 0) is on the digital in-
put/output.
Indicates the status of the assigned signal is forcedly set
to 1.
Task navigation