Special Functions | Dynamic Collision Monitoring (option 40)
Temporarily activating and deactivating collision monitoring via
program control
Open the NC program in Programming mode
Place the cursor at the desired position, e.g. before Cycle 800 to
enable eccentric turning
Press the SPEC FCT key
Press the PROGRAM FUNCTIONS soft key
Shift the soft-key row
Press the FUNCTION DCM soft key
Select the condition with the corresponding soft
key:
FUNCTION DCM OFF: This NC command
temporarily deactivates collision monitoring.
The deactivation is effective only until the
end of the main program or until the next
FUNCTION DCM ON. When another NC
program is called, DCM is active again.
FUNCTION DCM ON: This NC command
cancels an existing FUNCTION DCM OFF.
The settings applied with the FUNCTION DCM function
are only effective in the active NC program.
After terminating the program run or selecting a new
program, the settings made for Program run and
Manual operation with the COLLISION soft key become
effective again.
Further information:
and deactivating collision monitoring", page 490
Symbols
Symbols in the status display show the condition of collision
monitoring:
Icon
Function
Collision monitoring active
Collision monitoring is not available
Collision monitoring is not active