LANDTEC GEM5000 Operating Manual page 7

Gas analyzer
Hide thumbs Also See for GEM5000:
Table of Contents

Advertisement

GEM5000 Gas Analyzer
from being adversely affected, thus ensuring that the type of protection is not
compromised.
The relative pressure range is +/-500 mbar. Note, however, that the input pressure
should not exceed +/- 500 mbar relative to atmospheric pressure and the output
pressure should not exceed +/- 100 mbar relative to atmospheric pressure.
For CSA (Canada) the 5000 series of gas analysers are certified to Hazardous
Area Classification
CLASS 2258 03 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non-
Incendive Systems - For Hazardous Locations
Ex ib IIA:
Model GA 5000, GEM 5000 and BIOGAS 5000 Methane Detectors; portable, battery
powered with non-field-replaceable Battery Pack P/N 20087 or 2011113; intrinsically safe
and providing intrinsically safe circuits ("[ib]" for Zone 1) to Model GF5.2 Temperature
Probe (Connector B) and with entity output parameters as tabulated below; Temperature
Code T1; -10 ºC  Tamb.  +50ºC.
Connector
B
C
 Note:
This device has been investigated for electrical safety features only.
For CSA (USA) the 5000 series of gas analysers are certified to Hazardous Area
Classification
CLASS 2258 83 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non-
Incendive Systems – For Hazardous Locations - CERTIFIED TO U.S. STANDARDS
AEx ib IIA:
Model GA 5000, GEM 5000 and BIOGAS 5000 Methane Detectors; portable, battery
powered with non-field-replaceable Battery Pack P/N 20087 or 2011113; intrinsically safe
and providing intrinsically safe circuits ("[ib]" for Zone 1) to Model GF5.2 Temperature
Probe (Connector B) and with entity output parameters as tabulated below; Temperature
Code T1; -10 ºC  Tamb.  +50ºC.
Connector
B
C
Note:
This device has been investigated for electrical safety features only.
Uo
Io
(V)
(mA)
5.0
6
10.0
5
Uo
Io
(V)
(mA)
5.0
6
10.0
5
Entity Parameters
Po
Co
(mW)
(uF)
7
100
50
100
Entity Parameters
Po
Co
(mW)
(uF)
7
100
50
100
OMGEM5KN4.7.1
Lo
Ci
(mH)
(uF)
1000
0
1000
0
Lo
Ci
(mH)
(uF)
1000
0
1000
0
Page 7 of 70
Li
(mH)
0
0
Li
(mH)
0
0