4.5 Attaching and connecting the sewing light transformer (optional equipment)
3
2
Fig. 19
Caution!
The sewing light transformer is directly connected to the mains supply. It is
therefore live even when the main switch is switched off.
The mains plug must be removed before conducting any work on the sewing
light transformer, e.g. when changing the fuse.
– Remove the special machine's mains plug!
– Route the mains cable 1 of the sewing light transformer 2 through the
cable duct 3 and up to the main switch.
It is connected to the mains-connection side of the main switch (or motor-
protection switch).
– See connecting diagram 9800 169002B.
– Stick the adhesive label with the safety instructions onto the front of the
main switch.
1
15