2.
Pulse Trigger
Setup a certain trigger condition to capture specified pulse. Pulse tigger occurs
when pulse width meets the condition.
(1) :TRIGger:PULSe:MODE
Command Format:
:TRIGger:PULSe:MODE□<mod>
Function:
The command sets the trigger condition as +Greaterthan (positive pulse
width greater than), +Lessthan (positive pulse width less than), + Equal
(positive pulse width equal), -Greaterthan (negative pulse width greater
than), -Lessthan (negative pulse width less than) or –Equal (negative pulse
width equal).
Query Format:
:TRIGger:PULSe:MODE?
Return Format:
The query returns +GREATER THAN or +LESS THAN, +EQUAL, -GREATER
THAN, -LESS THAN, –EQUAL.
Example:
:TRIGger:PULSe:MODE□+GREATERTHAN
Set the trigger condition as positive pulse widrh greater than.
:TRIGger:PULSe:MODE?
(2) :TRIGger:PULSe:WIDTh
Command Format:
:TRIGger:PULSe:WIDTh□<wid>
Function:
The command sets the pulse width. The <wid> range is 20ns ~10s.
Query Format:
:TRIGger:PULSe:WIDTh?
Return Format:
The query returns the value of pulse width, and the unit is s.
2-62
Return +GREATER THAN.