Rigol DS1204B Programming Manual page 16

Digital oscilloscope, ds1000b series
Hide thumbs Also See for DS1204B:
Table of Contents

Advertisement

RIGOL
1.
:KEY:LOCK
Command Format:
:KEY:LOCK□{ ENABle | DISable }
Function:
The command enables and disables the function of Remote control on the keys
of front panel.
Query Format:
:KEY:LOCK?
Return Format:
The query returns ENABLE or DISABLE.
Example:
:KEY:LOCK□ENABle
:KEY:LOCK?
2.
:KEY:RUN
Command Format:
:KEY:RUN
Function:
This command controls the running state of the oscilloscope. The oscilloscope
will cutover between RUN and STOP when sending this command continually.
3.
:KEY:AUTO
Command Format:
:KEY:AUTO
Function:
The command sets oscilloscope automatically to display the waveform to be
optimal condition.
4.
:KEY:SINGLe
Command Format:
:KEY:SINGLe
2-8
Enable remote control on the keys of front panel .
Return ENABLE.