5.
:DISPlay:MNUStatus
Command Format:
:DISPlay:MNUStatus□{{1|ON}|{0| OFF}}
Function:
The command sets menu display function ON (Performing menu operation) or
OFF (viewing the waveform).
Query Format:
:DISPlay:MNUStaus?
Return Format:
The query returns 1 or 0, respectively indicates ON or OFF.
Example:
:DISPlay:MNUStatus□ON
:DISPlay:MNUStaus?
6.
:DISPlay:SCReen
Command Format:
:DISPlay:SCReen□<scr>
Function:
The command sets the display mode of screen. The <scr>may be Normal
(normal display mode) or Inverted(inverted display mode).
Query Format:
:DISPlay:SCReen?
Return Format:
The query returns NORMAL or INVERTED.
Example:
:DISPlay:SCReen□NORMal
:DISPlay:SCReen?
7.
:DISPlay:CLEar
Command Format:
:DISPlay:CLEar
Programming Guide for DS1000B Series
Set menu display function on.
Return 1.
Set the screen as normal display mode.
Return NORMAL.