ES64U SNMP MIB description
...................................................................................................................................................................................................................................
MIB field name
tsdimEFDIndex
(RC)
tsdimEFDDest
(RC)
tsdimEFDPort
(RC)
tsdimEFDRowStatus
tsdimEFDManagerIndex
TsdimAlarmSevDefault
The default severity value used for new profile index/trap ID pairs that have not yet been
modified.
This value is also used whenever an object's alarm severity profile index is set to 0. The
default value of this object is indeterminate(5).
Object identifier (OID):
1.3.6.1.4.1.637.54.1.1.3.1.26
Full path:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).alcatel(637).ltt(54).tsdim(1).tsdimBasicMib(1).
tsdimSupportMib(3).tsdimSupportMibObject(1).tsdimAlarmSevDefault(26)
TsdimAlarmSevProfileIndexNext
This object contains an appropriate value to be used for
tsdimAlarmSevProfileIndex
tsdimAlarmSevProfileTable
The value –1 indicates that no unassigned entries are available.
To obtain the index value for a new entry, the manager issues a management protocol
retrieval operation to obtain the current value of this object. After each retrieval, the agent
should modify the value to the next unassigned index (or -1).
...................................................................................................................................................................................................................................
1-34
tsdimEFDTable
Running Index of the table
IP address of the manager
UDP port
Used to create, modify or delete a row in
the table
(RC)
Pointer to the equivalent index in
opticsIMMgrPollingInfoTable
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
MIB tables for alarm/trap/event management
(manager list MIB)
Description
when creating entries in the
.
Alarms and events
Value
Ethernet interfaces value as in IfTable
Default 162 as in standard
CreateAndWait, Active, otInService, or
Destroy
Index number