ES64U SNMP MIB description
...................................................................................................................................................................................................................................

Alarms and events

Trap mechanism

To use the trap mechanism you should use the following features:
Manager list
Define to which IP address and UDP port to send the traps:
You need to use 2 tables: (duplicate tables for future usage of filtering)
opticsIMMgrPollingInfoTable
tsdimEFDTable
Maximum configured managers is 10.
Alarm profiles
Define profile for specific/group/all sources of alarm to use.
By default there are 4 profiles defined – those defaults can not be edited.
You can define up to 96 new alarm profiles.
Each profile defines the severity for each possible alarm.
For profile definition you need to use 2 tables:
tsdimAlarmSevProfileTable
tsdimAlarmSevTable
If the severity can not be found within the relevant profile definition, the trap will use a
default (minor).
tsdimAlarmSevDefault
By default all sources pointed to profile #2 (=primary alarms)
tsdimIfAsapIndex
Open Alarm Table
Show the open alarms table
tsdimAPTTable
...................................................................................................................................................................................................................................