Receptacle will be located
below VersiCharge mounting
bracket, either to the left or
the right of the stud to which
the mounting bracket will be
attached. Verify receptacle
location complies with local
code requirements.
o NEC® 2011 specifies:
Indoor (NEC® Article
625.29B) = installation 18 –
48 inches above ground
level.
o Verify local code with
respect to installation
height.
Wire a standard NEMA 6-50
receptacle using appropriate
wire.
Using 7/16 inch socket head
and drill, attach the mounting bracket to
the wall using two lag screws provided.
Verify that lag screws are going into the
stud.
Hang the VersiCharge on the Mounting
Bracket by first hooking the bottom of the
unit into the mounting slot and then
hooking the top into the mounting tab.
Secure VersiCharge to wall and mounting
bracket using provided screws.
Plug the VersiCharge into the receptacle.