Download Print this page

Siemens VersiCharge Installation And Operation Manual page 19

Hide thumbs

Advertisement

Remove the cord-and-plug assembly from the conductor opening
o Disconnect the attachment plug wires from
the terminal block by loosening screws in
position 1, 2, and 3.
o Do not adjust the two screws on top of the
terminal block unit. These are for factory use
only.
o Disconnect and remove strain relief and
entire cord-and-plug assembly
Continue with directions in 'Wiring Steps for
Hard-Wired Installation' starting at 'Proper
strain relief is required for conduit connection'
Wiring Steps for Hard-Wired Installation
Open hinged cover by loosening four cover Phillips closure screws.
Remove barrier by removing the two securing screws.
DANGER
Power before working on this equipment by turning the circuit breaker to
which this circuit is wired to the off position.
Chose appropriate conduit hub depending on whether your installation is
inside or outside. Outdoor installations must be completed with a water tight
conduit hub. We recommend flexible conduit for easier use during
installation.
19
Hazardous voltage. Will cause death or serious injury. Turn off
©
813776

Hide quick links:

Advertisement

loading