Locate a stud within the wall to attach the mounting bracket and receptacle.
For concrete or masonry walls, install appropriate anchors.
Verify that the stud or anchor and surrounding materials can handle the 20+
lbs load of the VersiCharge.
Verify local code with respect to installation height:
o Installation height is regulated by NEC®; however this can vary based on
local jurisdiction.
o NEC® 2011 specifies:
Using 7/16 inch socket head and drill, attach the Mounting Bracket to the
wall using the two lag screws, ensuring that the cutout lines up with the
conduit and that the two lag screws are going into the stud.
Route conduit to the opening of the unit and terminate appropriately.
Route conductors, with proper strain relief, into the VersiCharge from the
conductor opening
o Pull 3-6 inches of slack through the conductor opening
Place bottom mounting tab into corresponding slot in mounting bracket.
Secure VersiCharge to wall and mounting bracket
Wire conductors (copper only) into device (L1, L2 and Ground) from
connected conduit. Using torque screw driver, torque all lugs to 14.5 lb-in.
Replace barrier and secure with the two screws which were removed in the
beginning.
Rotate the unit towards the wall so that the hook on the unit goes over the
top mounting bracket.
Replace hinged cover, securing with four Phillips head screws
Secure VersiCharge to wall and mounting bracket
20
Indoor (NEC® Article 625.29B) = installation 18-48 inches above
ground level
Outdoor (NEC® Article 625.30B) = installation 24-48 inches above
ground level
©