Cisco D9800 Reference Manual page 152

Network transport receiver
Hide thumbs Also See for D9800:
Table of Contents

Advertisement

Input Configuration Command
URI Argument
fec
mod
rolloff
Iq
pwr
sel22khz
lo1
lo2
xover
pol
Cisco D9800 Network Transport Receiver Version 2.75 RESTful Web Services API Reference Guide
140
Description
FEC Mode
Type: String
Values: "Auto", "1/2", "2/3", "3/4", "5/6", "7/8"
Modulation Type of DVB-S2 must use a FEC value of "Auto"
Modulation Type
Type: String
Values: "DVBS" or "DVB-S2"
Rolloff Factor
Type: String
Values: ".20", ".25", ".35", "Auto"
IQ Mode
Type: String
Values: "Opposite", "Normal", "Auto"
LNB Power
Type: String
Values: "Off", "13V", "18V", "H-NIT", "V-NIT"
22 KHz Selection
Type: String
Values: "Off", "On", "Auto"
LO Select 1
Type: Float
Values: 0.0 ... 15.0
LO Select 2
Type: Float
Values: 0.0 ... 15.0
Cross Over Frequency
Type: Float
Values: 0.0 ... 15.0
Polarization
Type: String
Values: "Horizontal", "Vertical", "Auto"