Technical Data - Graco Dyna-Star 77X000 Instructions Manual

Hp and hf pumps
Table of Contents

Advertisement

Technical Data

Dyna-Star HP or HF Lubrication Pump
Maximum Working Pressure
HF Models
HP Models
Electrical Requirements
All Models
Wire Terminal AWG Size for Control Board
Input Voltage Range
24 VDC
ON/OFF Signal Voltage Range and Current
Voltage Range
Drive Resistance
Peak Operating Current
24 VDC
Peak Power
24 VDC
Pump Output
HF Models
HP Models
Weight - Pump Only
35 - 60 lb Tank / Reservoir
90 - 120 lb Tank / Reservoir
400 lb Tank / Reservoir
Wetted Parts
Pump Wetted Parts
Operating Temperature
HP Models
HF Models
Storage Temperature HP and HF Models
Humidity Level
IP Rating
Audible Sound Pressure*
1000 psi (6.89 MPa, 58.95 bar) Models
2000 psi (13.79 MPa, 137.9 bar) Models
3000 psi (20.68 MPa, 206.84 bar) Models
4000 psi (27.58 MPa, 275.79 bar) Models
5000 psi (34.47 MPa, 374.74 bar) Models
Cable
Cable Gland Thread
Cable Range
*Sound power was measured per ISO-9614-2.
332514J
US
3500 psi
5000 psi
See Performance Charts, beginning on page 41
50 lb.
55 lb.
60 lb.
steel, polyurethane, acetal, buna-N, aluminum,
polyester elastomer
-40° to 149°F
14° to 149°F
-40° to 149°F
90%
IP69K
70.7 dB(A)
71.4 dB(A)
71.4 dB(A)
71.2 dB(A)
70.6 dB(A)
M25
0.36 - 0.64 in.
Metric
24.1 MPa, 241 bar
34.47 MPa, 344 bar
24VDC
24 to 10 AWG
18 to 32 VDC
5 to 32 VDC
1.1K
35A
720W
22.7 kg
25.0 kg
27.2 kg
-40° to 65°C
-10° to 65°C
-40° to 65°C
9 - 16 cm
Technical Data
39