Graco Dyna-Star 77X000 Instructions Manual page 29

Hp and hf pumps
Table of Contents

Advertisement

5. Remove screws (116) from motor control box cover
(120) and remove cover and gasket (119) (F
119
120
116
F
. 53
IG
6. Remove nuts (134) as shown in F
washers (135) and motor wires from terminals.
Save these parts to use them for reassembly.
134
115
134
135
F
. 54
IG
332514J
. 53).
IG
. 54. Remove
IG
117a
7. Disconnect sensor cable (117a) from motor control
board (F
. 54).
IG
8. Use a wrench to loosen strain relief (a) and remove
wiring harness from housing (F
a
115
F
. 55
IG
9. Remove screws (125) and washers (124) holding
motor (123) to gear box housing (101). Remove
motor. Verify o-ring (122) was removed with motor.
(F
. 56)
IG
If o-ring (122) is still inside the gear box housing
(101), remove it.
Discard these parts in accordance with all safety
regulations.
101
122
F
. 56
IG
Repair
. 55).
IG
123
124
125
29