Graco Dyna-Star 77X000 Instructions Manual page 34

Hp and hf pumps
Table of Contents

Advertisement

Repair
5. Replace motor control board gasket (119) and cover
(120) with screws (116) (F
to pinch any wires. Tighten screws securely. Torque
to 17 - 19 ft lbs (23 - 25 N.m).
119
120
116
F
. 70
IG
6. Connect the timer/controller (F) (user supplied, if
used).
7. Connect High Pressure Lubricant Supply Line (D) to
the Lubricant Output Connection (0) (F
Vent Valve or Manifold.
0
D
F
. 71: Lubricant Outlet Connection
IG
8. Connect power to pump.
9. See Operation instructions for pump priming and
reservoir filling instructions, page 15.