Repair
5. Replace motor control board gasket (119) and cover
(120) with screws (116) (F
to pinch any wires. Tighten screws securely. Torque
to 17 - 19 ft lbs (23 - 25 N.m).
119
120
116
F
. 70
IG
6. Connect the timer/controller (F) (user supplied, if
used).
7. Connect High Pressure Lubricant Supply Line (D) to
the Lubricant Output Connection (0) (F
Vent Valve or Manifold.
0
D
F
. 71: Lubricant Outlet Connection
IG
8. Connect power to pump.
9. See Operation instructions for pump priming and
reservoir filling instructions, page 15.
34
. 70) being careful not
IG
. 71) on the
IG
332514J