Graco Dyna-Star 77X000 Instructions Manual page 32

Hp and hf pumps
Table of Contents

Advertisement

Repair
5. Remove screws (116) from motor control box cover
(120) and remove cover and gasket (119) (F
119
120
116
F
. 63
IG
6. Remove nuts (134) as shown in F
washers (135) and motor wires from terminals.
134
115
134
135
F
. 64
IG
32
. 63).
IG
. 64. Remove
IG
117a
7. Disconnect sensor cable (117a) from motor control
board (F
. 65).
IG
8. Disconnect source to power input (A and B) and
pump control connections (C and D) (See F
and Control Panel, page 13).
A
B
C
D
F
. 65
IG
9. Remove screws (118) securing motor control board
(117) to housing (115) (F
118
F
. 66
IG
10. Remove motor control board from housing and dis-
pose in accordance with all safety regulations.
. 65
IG
117a
. 66).
IG
117
115
332514J