Graco Dyna-Star 77X000 Instructions Manual page 33

Hp and hf pumps
Table of Contents

Advertisement

Reassembly
NOTE:
Use all new parts included in kit for reassembly.
1. Install new motor control board (117) in housing
(115) using screws (118) (F
in. lbs (0.9 - 1.1 N.m).
118
F
. 67
IG
2. Connect source to power input (A and B) and pump
signal connections (C and D) (F
page 13). Torque to 5.5 - 7 in. lbs (0.62 - 0.79 N.m).
A
B
C
D
F
. 68
IG
332514J
. 67). Torque to 8 - 10
IG
117
115
. 65 and A,B,C,D,
IG
3. Match green, yellow and blue wires of motor to ter-
minals of same color (written on the control board).
Secure wires to terminals using washers (135) and
nuts (134) (F
. 59). Torque to 8 - 10 in. lbs (0.9 -
IG
1.1 N.m).
134
115
134
135
F
. 69
IG
4. Connect sensor cable (117a) (F
Repair
117a
. 69).
IG
33