Motor Replacement: Kit 24T862 - Graco Dyna-Star 77X000 Instructions Manual

Hp and hf pumps
Table of Contents

Advertisement

Repair
NOTE: When the pump is correctly installed, the
breather (J) will be below the control box (115) as
shown in F
. 49.
IG
F
. 49
IG
27. Reinstall cover (126) using bolts (128). Use a
wrench to tighten bolts securely (F
126
F
. 50
IG
28. Connect the timer/controller (F) (user supplied, if
used).
29. Connect High Pressure Lubricant Supply Line (D) to
the Lubricant Output Connection (0) (F
Vent Valve or Manifold.
0
D
F
. 51: Lubricant Outlet Connection
IG
30. Connect power to pump.
31. See Operation instructions for pump priming and
reservoir filling instructions, page 15.
28

Motor Replacement: Kit 24T862

115
J
. 50).
IG
Disassembly
1. Disconnect Dyna-Star pump from main power
2. Relieve pressure (see Pressure Relief procedure,
128
3. Disconnect Timer/Controller (F) (user supplied, if
4. Disconnect High Pressure Lubricant Supply Line (D)
. 51) on the
IG
D
F
IG
Reference numbers used in the following instruc-
tions refer to Parts pages beginning on page 35.
Upper case letters used in the following instructions
refer to Typical Installation provided on page 6 or 7.
Lower case letters used in the following instructions
refer to component parts or user provided parts.
Unless otherwise noted, keep all parts for reassem-
bly. Inspect and clean parts as needed prior to using
them for reassembly.
Use all new parts included in kit for reassembly.
source.
page 8).
used).
to the Lubricant Output Connection (0) (F
the Vent Valve or Manifold.
0
. 52: Lubricant Outlet Connection
. 52) on
IG
332514J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents