21. Remove pump assembly from vise. Align hole
(212a) in displacement rod (212) (F
necting rod hole (102b) (F
through hole.
22. Slide spring (8) over pin (7) to secure pin in place.
Seat spring in groove (102a) in connecting rod (102)
to prevent it from moving during pump operation.
23. Align the two gasket seals (9) in pump adapter (2)
with two holes (103b) in gear box pump bracket
(103). Push the pump lower and pump assembly
together (F
. 45).
IG
103
103b
9
2
F
. 45
IG
24. Secure pump adapter (2) to pump upper (pu) using
screws (6). Use a socket to tighten screws securely
(F
. 46). Torque to 7-9 ft lbs (9-12 N.m).
IG
2
6
F
. 46
IG
332514J
. 43) with con-
IG
. 44). Insert pin (7)
IG
pu
25. For Tube-In-Tube models only: Install gasket (5)
and Tube-In-Tube (3). Secure Tube-In-Tube to
pump adapter (2) using screws (4). Use a socket to
tighten bolts securely (F
(9-12 N.m).
NOTE: Tube-In-Tube Replacement Kits 24T863 for
60 pound pumps, 24T864 for 90 pound pumps, and
24T865 for 400 pound pumps are available from
Graco. See Parts, page 38 for information about
ordering these kits or contact your Graco Distributor
or Graco Customer Service.
3
4
F
. 47
IG
26. Align holes in pump base with holes in tank / reser-
voir cover. Securely fasten pump to tank / reservoir
cover using screws (a) and washers (b) (F
Be careful when installing pump to base that wire har-
ness to motor is not caught between the pump and the
hole on top of the reservoir. If the wire harness is
caught between the pump and reservoir, the wires
could be damaged.
F
. 48
IG
. 47). Torque to 7-9 ft lbs
IG
2
5
IG
NOTICE
a
Repair
. 48).
b