System Description; System Limitations - Rotax 915 iSc 3 A Installation Manual

915 i a series
Hide thumbs Also See for 915 iSc 3 A:
Table of Contents

Advertisement

For a detailed system description refer to the latest issue of the Operators Manual.

SYSTEM LIMITATIONS

Under no circumstances consumer cables must be routed alongside the ignition
Valid installation
The Fusebox must not be installed in the cockpit. Installation is only allowed in the engine
positions
compartment.
Component tem-
Limitations see Chapter 00-00-00 Approval of electric and electronic components.
peratures
limitation
The Regulator temperature must be measured as shown within the following figure:
Figure 3.2: Regulator temperature measurement area
Separation of
A connection between regulator plate A (EMS ground) and airframe ground should only
EMS and Airframe
be done during supply of the EMS System by an external power source (e.g. during en-
circuit
gine start). Although it would have no impact on the redundancy of the EMS, the fault tol-
erance of the system may be declined in case the EMS ground is connected permanently
with the airframe ground.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
INSTALLATION MANUAL

SYSTEM DESCRIPTION

ATTENTION
cables. There is a risk of electromagnetic interference.
Rectifier regulator
1
Component temperature meas-
2
urement area
24–00–00
December 01 2017
Page 3