Setting Brix; Testing Brix Level - Cornelius FRUTISTA VIPER 3 FLAVOR Installation Manual

Hide thumbs Also See for FRUTISTA VIPER 3 FLAVOR:
Table of Contents

Advertisement

Step
4
5
6
7
8

Setting BRIX

BRIX is important to the quality of the final product. The BRIX menu provides a measured amount of product with
a constant volume so that a BRIX comparison can be made between samples. The unit is set to provide a three
second dispense of the product for BRIX testing.

Testing BRIX Level

The BRIX Setup menu is located on the Maintenance menu. The Maintenance menu is shown in Figure 20.
The BRIX Setup menu facilitates the extraction of a sample of product from the unit for BRIX measurement.
There is a three second dispense that produces a constant volume dispense so that BRIX comparison can be
made between samples.
Step
1
2
3
4
5
6
7
© 2010-2016, Cornelius Inc.
Table 15.
Manually press the syrup valve at the front of the unit (Figure 19.) to fill the
syrup system.
When syrup flows from the sample tube, the system is full
Check the system for syrup leaks.
Repeat Steps 2 through 5 for each barrel in the unit.
Verify that the Do Not Drink and Out of Product lights go off on all barrels
and the "Syrup Out" message clears.
SELECT
BARREL MAINT
MANUAL DIAG
TOTALS
BRIX SETUP
12:51P
MOTOR SETUP
MAR 04
SYSTEM
BACK
MAIN
SETUP
Figure 20.
Table 16.
Remove the drip tray by sliding it forward off the mounting brackets.
Remove the splash panel behind the drip tray (if not removed).
Turn product supply valve to the Down (BRIX) position for the barrel you are
going to test. (See Figure 21.)
From the Maintenance menu (Figure 20.), open the BRIX Setup menu.
NOTE: Entering the BRIX Setup menu turns off all the
barrels in the system.
Use the up and down arrows to highlight BRIX SETUP. Press the GO button
at the bottom of the display.
Again use the up and down arrows to select the barrel you wish to perform
BRIX on.
NOTE: Pressing CANCEL will stop the process.
Locate the appropriate barrel sample tube and hold a cup under it.
Action
MAINT
GO
Action
- 23 -